380V Surge Protective Device EL1-D-20 Video
Class D Yellow Surge Protector 380V Surge Protective Device EL1-D-20 Application scope
Power industry: The power system is the main victim of lightning disasters. Lightning strikes can cause serious consequences such as overheating, short circuit, and explosion of power equipment, affecting the stability and safety of power supply. Therefore, the power industry needs to install surge protectors in key locations such as substations, distribution rooms, transmission and distribution lines, generators, etc. to prevent lightning from causing damage to the power system. Class I and II switch-type surge protectors are usually used to withstand the impact of large currents.
Communications industry: Communications equipment and network systems are very sensitive to surge voltages. Once struck by lightning or other interference, it may cause data loss, communication interruption, or equipment damage. Therefore, the communications industry needs to install surge protectors at all levels, including base stations, switches, routers, servers, terminal equipment, etc. Combined surge protectors of Class I, II and III are usually used to achieve hierarchical protection.
Construction industry: Buildings are important objects of lightning protection. Various electronic equipment inside the building need to be protected from the effects of lightning strikes and surges. Therefore, the construction industry needs to install surge protectors at different levels such as main distribution boxes, distribution boxes, and terminal equipment to achieve partitioned protection. Generally, voltage-limiting surge protectors of Class I, II and III are used to reduce the level of protection.
380V Surge Protective Device SIZE
Class D Yellow Surge Protector 380V Surge Protective Device EL1-D-20 Date
Categories | SPD Surge Protective Device |
Model | EL1-D-20 |
Parameters | EL1-D-20 |
Maximum continuous operating voltage Uc(V~) | 420V 385V 275V |
Voltage protection level UP(KA) | ≤1.2 ≤1.0 ≤1.0 |
Maximum dischargecurrent(8/20us)(KÄ) | 10 |
Nominal dischargecurrent (8/20us) (KA) | 5 |
Response time (ns) | <25 |
IP Grade | IP20. |
quipped with front fuse or circuit breaker | 10A 16A |
Application | Incoming line first level protection |
Remark | Other maximum continuous working voltage Uc can be customized |
Class D Yellow Surge Protector 380V Surge Protective Device EL1-D-20 DESCRIPTION OF PRODUCTS
are suitable for ac 50/60hz, rated voltage380V IT. TT. TN-C. TN-S. TN-C-Sand other power supply systems to protect the surge caused by indirect
lightning and direct lightning or other instantaneous overvoltage. Class III SPDaccording to IEC61643-1:1998-02. Class D surge protectors.
SPD has common mode (MC) and differential mode (MD) protection.The SPD accord with GB18802.1 /lEC61643-1.
Class D Yellow Surge Protector 380V Surge Protective Device EL1-D-20 MAIN TECHNICAL PARAMETERS
Parameters | Model | |||||
EL1-D-10 | EL1-D-20 | |||||
Maximum continuous operating voltage Uc(V~) | 420V | 385V | 275V | 420V | 385V | 275V |
Voltage protection levelUP(KA) | ≤1.5 | ≤1.2 | ≤1.0 | ≤1.2 | ≤1.0 | ≤1.0 |
Maximum discharge current(8/20us) (KA) | 20 | 10 | ||||
Nominal discharge current (8/20us) (KA) | 10 | 5 | ||||
Response time (ns) | <25 | |||||
IP Grade | IP 20 | |||||
Input leads sectional area (mm²) | 6 | |||||
Transversal area of Ground _ lead (mm²) | 16 | |||||
Type selection of fuse or circuit breaker(A) | 16A、20A | 10A、16A | ||||
Work environment (℃) | -40℃~+85℃ | |||||
Remote Defect Indication | Aging failure: green normal, red failure | |||||
Application | Incoming line second level protection | |||||
Remark | Other maximum continuous working voltage Uc can be customized |
Keywords:380V Surge Protective Device,380V Surge Protector,Yellow Surge Protector,Class D Surge Protector
> What is the role of a fuse?
A fuse refers to an electrical device that, when the current exceeds a specified value, uses the heat generated by itself to fuse the melt and disconnect the circuit...
> Precautions for the working principle of molded case circuit breakers
The molded case circuit breaker adopts a heat release contact. When the current exceeds the rated value, the contact is heated, causing the spring force to decrease,...
> The difference between fast fuse and ordinary fuse
Fast fuse is a kind of fuse, fast fuse is used for short circuit protection of semiconductor rectifier components or circuit breakers. Because the overload capacity ...
> The meaning and working principle of RCCB, and a few points you want to know
This article will tell you about the working principle, function, and main structure of residual current circuit breaker (RCCB), and solve customers' concerns about ...